Specialists in
the controlled application of lubricants
|
|||
|
|
![]() |
SYSTEM DESIGN |
DUAL LINE SYSTEM | |||
|
|
|||||
|
The Dual line system is most effective on large area systems feeding machine bearings and slide ways. As the title suggests this system works on a two pipe installation and initial cost can be high, however it is a very robust system and will stand up to a heavy industrial environment. |
||
| Standard alarms for this system are | ||
|
LOW RESERVOIR
|
PUMP
OVER RUN TIME
|
PUMP
MOTOR TRIPPED
|
|
(no
grease in reservoir)
|
(could
be a leaking pipe)
|
(system
blockage or pump fault)
|
| The two pipes are run from the pump station all round the area to be served. At each distribution point a metering block is fixed and connected to each pipe | ||
|
000 |
||
|
The above
photograph shows a pump station complete with control panel and pump.
Pneumatic pumps in drums are preferred in this system. To save unnecessary
transferring and possible contamination.
|
If there are
critical bearings or inaccessible areas that need monitoring, switches
can be fitted to the outlets and connected to the control panel where
alarms can show individual or area faults.
|
The outlets
from each block are Connected to the point of application
|
|
|
||||
|
Controlled
Lubrication
|
||||
|
|
||||
|